Pressure sensor with I�C communication ? possibilities and boundary conditions

I�C was designed to communicate over short distances between printed circuit boards and is really a simple, 8-bit serial data bus. In the meantime, it is not only PCB-mountable pressure sensors that utilize the I�C signal for data transfer, but additionally pressure sensors remote from customer electronics.
Remote sensors will often have the benefit of being less sensitive to contaminated or aggressive media and having the capacity to measure directly at the process. In the case of sensors mounted directly on the circuit board, the sensor element is, in many cases, exposed right to the medium. With Energetic , steel or ceramic generally serve as the wetted surface.
I�C circuit
The I�C bus, alongside the two supply lines, requires only two further lines:
SCL (serial clock line)
SDA (serial data line)
Additional possibilities through I�C
The I�C bus is a well-known standard in electronics, offering additional possibilities for communication with a pressure sensor than having an analogue signal:
In the data protocol, in addition to the pressure value, a temperature value and diagnostic information (for instance an integrity test of the info transfer) could be transmitted via a status byte.
Several pressure sensors can be linked to a bus line as ?slaves? to the client electronics that functions as a ?master?.
On the client side, as opposed to using pressure sensors with analogue signals, the analogue-to-digital conversion of the pressure value for further signal processing is unnecessary because the pressure value has already been present in digital form. This contributes to faster and easier signal processing.
The electronics for communication could be built with standard components easily available on the market.
Often, I�C signal pressure sensors are also optimised to consume less energy, making them perfect for battery-powered applications. In the WIKA portfolio, for instance, this applies to the MPR-1 pressure sensor module.
Boundary conditions with the use of I�C
Since I�C isn’t a fieldbus, long wire lengths are not recommended. The utmost wire length depends, in detail, on the operating environment and the corresponding disturbing influences. I�C communication is best used in projects where in fact the pressure sensor or the pressure sensor module is built-into the customer product and therefore protected against external influences. It should also be noted that with any digitally processed signal, the response time because of discrete-time sampling will be somewhat slower than for an analogue, continuous signal.
Note
Breathtaking will be happy to assist you to with any further questions on digital interfaces.
Distributed Intelligence
Distributed Intelligence on the integration of pressure sensors into hydraulic systems
Fill below form and we will send you the whitepaper ?Distributed Intelligence?.
Name
Company
E-mail
Send
We?re focused on your privacy. We?ll use your details to contact you about our services and products. Contact us at socialmedia@wika.com to revoke your permission to utilize your information.

Leave a Comment